BRQDM - FLOWSOLDER ALLOYS
- MSDS: BRQDM
- Manufacturer: FEDERATED FRY METALS INC DIV OF COOKSON AMERICA
- Product Name: FLOWSOLDER ALLOYS
- National Stock Number: 3439-00-614-9672
Product Identification
Product ID:FLOWSOLDER ALLOYS
MSDS Date:01/29/1991
FSC:3439
NIIN:00-614-9672
MSDS Number: BRQDM
Responsible Party
ALTOONA, PA 16602
US
Emergency Phone: 814-946-1611/CHEMTREC 800-424-9300
Info Phone: 814-946-1611/FAX 814-944-8094
Preparer: DON PORTER
Cage: 65172
Contractor
Telephone: 814-946-1611
Cage: 65172
Ingredients
TIN
CAS: 7440-31-5
RTECS: XP7320000
Fraction By Weight: <100%
OSHA PEL 2 MG/M3
ACGIH TLV: 2 MG/M3; 9293
LEAD (SARA III)
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: <100%
OSHA PEL 0.05 MG/M3;1910.1025
ACGIH TLV: 0.15 MG/M3;DUST 9293
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ANTIMONY (SARA III)
CAS: 7440-36-0
RTECS: CC4025000
Fraction By Weight: <15%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG SB/M3; 9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
SILVER (SARA III)
CAS: 7440-22-4
RTECS: VW3500000
Fraction By Weight: <10%
OSHA PEL 0.01 MG/M3
ACGIH TLV: 0.1 MG/M3; 9293
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
BISMUTH
CAS: 7440-69-9
RTECS: EB2600000
Fraction By Weight: <60%
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION/INGESTION MAY CAUSE
LEAD BASED NERVOUS SYTEM DISORDERS. CHRONIC: PROLONGED OR REPEATED
EXPOSURE MAY CAUSE SYTEMIC POISONING; DAMAGE TO BLOOD-FORMING
ORGANS, NERVOUS SYSTEM, KIDNEYS, AND REPRODUCTIVE SYSTEMS.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALED/INGESTION: METALLIC TASTE, ANEMIA,
INSOMNIA, WEAKNESS, CONSTIPATION, ABDOMINAL PAIN, JOINT & MUSCLE
PAIN, MUSCULAR WEAKNESS.
Medical Cond Aggravated by Exposure:DISEASES OF BLOOD AND BLOOD-FORMING
ORGANS, KIDNEYS, NERVOUS AND POSSIBLY REPRODUCTIVE SYSTEMS.
First Aid
First Aid:INHALATION: REMOVE FROM EXPOSURE AND CALL A DOCTOR. SKIN:
WASH WITH SOAP AND WATER. EYES: FLUSH WITH LOTS OF WATER FOR 15
MINUTES, HOLD LIDS OPEN. SEE DOCTOR. INGESTED: IF CONSCIOUS, GIVE
LOTS OF WATE R. GET MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONE
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL. DO NOT USE WATER ON
MOLTEN METAL.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:MOLTEN METALS PRODUCE FUME OR VAPOR THAT
MAY BE TOXIC AND/OR RESPIRATORY IRRITANTS.
Accidental Release
Spill Release Procedures:ALLOW TO SOLIDIFY AND COLLECT IN SEALED DRUMS
FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. USE LOWEST
POSSILBLE TEMPERATURE TO MELT. AVOID CREATING DUSTS, MINIMIZE
FUMES. USE PROPER VENTILATION.
Other Precautions:SPECIAL ATTENTION IS DRAWN TO THE REQUIREMENTS OF THE
OSHA LEAD STANDARD (1910.1026) AND RESPIRATOR STANDARD SHOULD
AIRBORNE EXPOSURES EXCEED THE OSHA ACTION LEVEL OR PEL. NO FOOD,
DRINK, OR SMOKING A LLOWED IN WORK AREAS.
Exposure Controls
Respiratory Protection:IF ENGINEERING CONTROLS FAIL OR NON-ROUTINE USE
OR EMERGENCY OCCURS; USE NIOSH/MSHA APPROVED RESPIRATOR FOR TOXIC
DUST AND/OR FUME. SEE 29 CFR 1910.125 SUBPART (F) OF OSHA LEAD
STANDARD.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION TO MAINTAIN EXPOSURES
BELOW OSHA ACTION LEVEL OR PEL.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE NORMALLY REQUIRED.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
Chemical Properties
HCC:N1
Melt/Freeze Pt:M.P/F.P Text:>360F,>182C
Spec Gravity:7-11
Evaporation Rate & Reference:N/R (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SILVER TO GREY METAL
Percent Volatiles by Volume:NIL
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG MINERAL ACIDS, REDUCING AGENTS,
HALOGENS.
Stability Condition to Avoid:MFR: NOT APPLICABLE. HMIS: CONTACT WITH
STRONG OXIDIZING AGENTS, STRONG MINERAL ACIDS, HALOGENS, REDUCING
AGENTS.
Hazardous Decomposition Products:LEAD FUMES AT TEMPERATURES ABOVE 800F.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS FOR LEAD.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.